Field Overview

Flare-to-power intelligence across the monitored fleet

Sites3
KPS Power Packages7
Installed Capacity18.5 MW
Gas Conditioned22,400 MCFD
Overall Flare-to-Power Efficiency
91%+1.2% vs yesterday

AI-derived score combining gas conditioning quality, generator availability, and power output vs. rated capacity across all monitored packages.

Drill-down

System Health

2 Critical 5 Watch 41 Nominal

Across Flare Gas Conditioning Train™ (FGCT) stages, NovaStar generator modules, and switchgear. Submetric detail lives in the operational dashboard.

Estimated

YTD Value & ROI

$612,4004.1× ROI

Four value streams tracked: flare gas monetized, diesel and grid power avoided, emissions and carbon credit value, and avoided unplanned downtime.

Financial values are estimates based on available operational data and customer-configured assumptions.

Liability converted to asset

Flare Reduction & Value Recovered

Full value detail

Flaring wastes energy, increases emissions, and creates regulatory exposure — this system converts that liability into a controlled, usable energy source.

Gas diverted from flare22,400MCFDvs 26,800 MCFD historical flare volume · 84% captured
Power generated YTD96,420MWh≈ 92 kWh of net generation per MCF of conditioned flare gas at fleet average.
Avoided flaring emissions41,860t CO2eEstimated, not zero-emissions — see ROI page for method.
Diesel / grid cost displaced$176,300Plus $284,600 of monetized gas value YTD.
AI Executive Summary

Flare-to-power efficiency is 6% below optimal capacity. The H2S removal bed on KPS-6 Unit B is approaching breakthrough, Generator Module 3 at Site 2 is showing rising exhaust temperature deviation, and the coalescing filter on the Site 1 conditioning skid has a climbing differential pressure consistent with early fouling.

Why is efficiency at this level?What should we fix first?
Prioritized by AI

Top Performance Issues

All alerts
Ranked by expected value

AI Recommendations

All recommendations
HIGHAI confidence 91%

Replace coalescing filter element

Site 1 · Conditioning Skid

Avoided generator fouling risk
$11,800estimated avoided damage
HIGHAI confidence 89%

Replace H2S media

KPS-6 Unit B · Site 3

Efficiency recovery +2.4%
$14,200estimated avoided curtailment
MEDIUMAI confidence 76%

Inspect Generator 3 exhaust valves

Site 2 · KPS-4.5

+1.6% availability
$8,400estimated avoided failure
LOWAI confidence 68%

Recalibrate Wobbe index monitoring

Site 3 · KPS-6 / KPS-3

Combustion efficiency +0.5%
$3,100estimated fuel savings
Expand coverage

Recommended FlareGuardian Upgrades

Real-Time Gas Composition Analyzer (GC)

Stream live Wobbe index, BTU content, and H2S/CO2 composition instead of periodic spot samples.

Why it matters: Combustion efficiency predictions currently rely on daily lab samples.

Benefit: Real-time fuel quality correlation with generator derating events.

Generator Vibration & Exhaust Monitoring

Per-cylinder exhaust temp + vibration sensors on each NovaStar generator module.

Why it matters: Today's diagnostics infer engine health from aggregate runtime and availability only.

Benefit: 2–3 weeks earlier warning on mechanical failures.

Methane & Emissions Telemetry

Add flare-stack and fugitive methane monitoring to the same asset model.

Why it matters: Emissions data currently lives outside FlareGuardian and isn't tied to conditioning-skid performance.

Benefit: Single compliance view + early leak detection tied to equipment degradation.

CMMS / Maintenance History Integration

Ingest work orders and parts consumption.

Why it matters: Failure-signature matching currently has no repair-outcome data attached.

Benefit: Higher-confidence predictions grounded in real repair costs.

Optional modules

FlareGuardian Add-On Bots

Flare-to-Power Revenue Bot

Tracks MCFD flared-gas converted to MWh generated, priced against live power/fuel offset rates, by day/week/month/YTD.

Emissions & Carbon Credit Bot

Quantifies avoided flaring volume as CO2e reduced and estimates carbon-credit/regulatory value.

Generator Fleet Benchmarking Bot

Compares identical NovaStar generator modules across all sites/packages to flag units drifting from peer performance, not just their own history.

Fuel Gas Quality Bot

Predicts conditioning-skid maintenance timing from H2S, moisture, particulate, and Wobbe index trends before they breach generator OEM fuel specs.

FGCT Fuel Quality Bot

Continuously trends Wobbe index and contaminant carryover against generator wear indicators — turning KenTech's oversized-conditioning claim into a measurable, provable generator-life extension metric versus minimal-filtration competitors.

Executive sales pilot · explore the process twin to see the live site schematic.